Nortek Awac 1 Mhz Sideview
Nortek AWAC 1 M Hz frontview
Nortek AWAC 1 M Hz topview
Nortek 30978278355 kopi
Nortek People Awac 1 Mhz Assemble
Nortek Awac 1 Mhz Sideview
Nortek AWAC 1 M Hz frontview
Nortek AWAC 1 M Hz topview
Nortek 30978278355 kopi
Nortek People Awac 1 Mhz Assemble

Oceanography

AWAC - 1 MHz

Real-time current profiles and directional waves for shallow water

  • Real-time current profiles to 30 m range; real-time directional waves to 35 m range
  • Acoustic surface tracking (AST) with vertical beam
  • Can be used both with fixed frames and subsurface buoys

Overview

The AWAC 1 MHz ADCP has become the standard reference technology in submerged wave-measurement applications. Thousands of these ADCPs have been deployed to capture the full wave spectrum in combination with current profiles. With a 35 m maximum range for wave measurements and 4 Hz sampling of the surface elevation, the AWAC 1 MHz is the optimal tool for shallow current and wave measurements.

  • Currents
  • Waves

Highlights

  • Real-time current profiles to 30 m range; real-time directional waves to 35 m range
  • Acoustic surface tracking (AST) with vertical beam
  • Can be used both with fixed frames and subsurface buoys

Usage

  • Online, real-time measurements of currents and waves
  • Design data for planning of new coastal structures
  • Site studies for offshore wind platforms
  • Coastal erosion studies
  • Monitoring of transient waves for channel wall protection

Setup

Designed for straightforward and reliable current and wave measurements in up to 35m of water, the AWAC 1MHz is configured using Nortek deployment software before installation. The AWAC is often considered the industry standard in wave measurements.

Deployment

AWACs are often bottom-mounted and/or implemented as part of real-time wave monitoring systems. Leading industry partners offer bespoke frames and buoys for the AWAC. Multiple communication protocols make simultaneous power and data transmission easy.

Data

Optional onboard wave processing allows real-time streaming of wave parameters to users onshore. Nortek’s SUV processing method (exclusive to AWACs and Signatures) enables quality wave measurements from a moving subsurface buoy. Nortek postprocessing software and/or display software is available for review or visualization of data, after deployment or in real time.

Download PDF

Maximum profiling range

30 m

Cell size

0.25-4.0 m

Number of cells

Typical 20-40, max. 128

Velocity range

±10 m/s horizontal, ±5 m/s along beam

Accuracy

±1% of measured value ±0.5 cm/s

Velocity precision

Consult instrument software

Maximum output rate

1 Hz

Internal sampling rate

7 Hz

Sampling

Same as velocity

Resolution

0.45 dB

Dynamic range

90 dB

Transducer acoustic frequency

1 MHz

Number of beams

3 beams 120° apart, one vertical beam (90° apart, one at 5° for platform mount)

Beam width

1.7°

Beam width vertical beam

1.7°

Maximum depth

35 m

Data types

Pressure, one velocity along each beam, AST

Sampling rate velocity (output)

2 Hz

Sampling rate AST (output)

4 Hz

No. of samples per burst

512, 1024 or 2048

Range

-15 to 15 m

Accuracy/resolution (Hs)

< 1% of measured value / 1 cm

Accuracy/resolution (Dir)

2° / 0.1°

Period range

0.5-50 s

Cut-off period (Hs)

5 m depth: 0.5 sec, 20 m depth: 0.9 sec, 60 m depth: 1.5 sec

Cut-off period (dir)

5 m depth: 1.5 sec, 20 m depth: 3.1 sec, 60 m depth: 5.5 sec

Temperature:

Thermistor embedded in housing

Temp. range

-4 to +40 °C

Temp. accuracy/resolution

0.1 °C/0.01°C

Temp. time response

< 5 min

Compass:

Magnetoresistive

Accuracy/resolution

2°/0.1° for tilt <15°

Tilt:

Liquid level

Accuracy/resolution

0.2°/0.1°

Maximum tilt

30°,AST requires <10° instrument tilt

Up or Down

Automatic detect

Pressure:

Piezoresistive

Range

50 m

Accuracy

0.5% of full scale (optional 0.1% of full scale)

Resolution

0.005% of full scale

No. of channels

2

Supply voltage to analog output devices

Three options selectable through firmware commands: Battery voltage/500 mA, +5V/250 mA, +12V/100 mA

Voltage input

0-5 V

Resolution

16-bit A/D

Capacity

9 MB standard, 4/16 GB (Prolog)

Profile record

Ncells*9 + 120 bytes

Wave record

Nsamples*24 + 1k bytes

Mode

Stop when full (default and Prolog) or wrap mode

Accuracy

±1 min/year

Backup in absence of power

1 year

I/O

RS-232 or RS-422. Software supports most commercially available USB– RS-232 converters

Communication baud rate

300- 115200 Bd

Recorder download baud rate

600/1200 kBd for both RS-232 and RS-422

User control

Handled via "AWAC AST" software, or ActiveX® controls. "Seastate" for online systems

Output formats

NMEA, Binary. Prolog provides same types also for processed wave and current data.

Bulkhead

MCBH-2-FS, MCBH-8-FS, optional Souriau M-series metal connector for online use

Cable

PMCIL-8-MP on 10 m polyurethane cable, metal connector optional

Functions

Deployment planning, instrument configuration, data retrieval and conversion. (for Windows®)

DC input

9- 18V DC

Maximum peak current

3 A

Avg. power consumption

0,65 W

Sleep current

< 100 μA

Transmit power

1-30W, 3 adjustable levels

Operating temperature

-4 to +40 °C

Storage temperature

-20 to +60 °C

Shock and vibration

IEC 721-3-2

EMC approval

IEC 61000

Depth rating

300m

Standard model

POM and polyurethane plastics with titanium fasteners

Maximum diameter

210 mm

Maximum length

175 mm

Weight in air

6.1 kg

Weight in water

2.9 kg

Polyurethane jacket, Shore D hardness, 13mm in diameter, max 2km. Inquire for longer cables

AWAC 1MHz General Arrangement-2 - NGA009-001 Rev.-

Declaration of conformity

AWAC 1 MHz, four beams

Symmetrical transducer orientation

Platform head

9 MB of memory on motherboard (M8)

4 GB SD card data logger

16 GB SD card data logger

ProLog with wave processing

Pressure sensor, 0-10 m

Pressure sensor, 0-20 m

Pressure sensor, 0-20m, accuracy 0,1% of FS

Pressure sensor, 0-30 m

Pressure sensor, 0-50 m

Pressure sensor, 0-50m, accuracy 0,1% of FS

Pressure sensor, 0-100 m

Pressure sensor, 0-100m, accuracy 0,1% of FS

Pressure sensor, 0-200m

10m RS232 polyurethane cable with 8-pin inline connector and USB converter

20m RS232 polyurethane cable with 8-pin inline connector and USB converter

30m RS232 polyurethane cable with 8-pin inline connector and USB converter

40m RS232 polyurethane cable with 8-pin inline connector and USB converter

50m RS232 polyurethane cable with 8-pin inline connector and USB converter

10m RS422 polyurethane cable with 8-pin inline connector and USB converter

20m RS422 polyurethane cable with 8-pin inline connector and USB converter

30m RS422 polyurethane cable with 8-pin inline connector and USB converter

40m RS422 polyurethane cable with 8-pin inline connector and USB converter

50m RS422 polyurethane cable with 8-pin inline connector and USB converter

Compass and tilt sensor

Without compass and tilt sensor

Deployment planning, execution and recovery

Deployment planning, execution and recovery

New features, fixes and functionality

Note. Firmware for legacy systems (pre April 2008) with version numbers starting with 0. or 1.

New features, fixes and functionality

Note. Firmware for legacy systems (pre April 2008) with version numbers starting with 0. or 1.

New features, fixes and functionality

Display of profiler data. Can be used in combination with Prof2NDP

Data conversion

Processing of waves

Data processing and ready-to-print reporting software. Request quote for license

Wave and current profile data visualization and processing software for online applications. Request quote for license

Analysis and processing of currents and directional waves. Request quote for license

Analysis and processing of current profiles. Request quote for license

Request a quote

Found the right product? Fill out the form to request a quote.

Cart

Total $0.00
Next

In the final step you can choose to pay by card or generate a quote PDF.